Linear & angular
Part 1: sizes and angles without individual indications. Nominal size sets the allowed deviation — larger features get more room.
Most-referenced guides
ISO 2768 is the general-tolerance note for linear and angular sizes that do not have their own band. It declutters a drawing. It is not a promise that every edge of a huge plate is “fine,” and it is not a substitute for a balloon on the three features you will measure incoming.
The standard exists so designers do not write ±0.1 on every non-critical length. Manufacturers get one class instead of a fight at incoming.
Part 1: sizes and angles without individual indications. Nominal size sets the allowed deviation — larger features get more room.
External radii and chamfer heights have their own small table. They are not the same as a linear length.
H and K come from the old Part 2 geometrical classes. Part 2 was withdrawn; new drawings may point at ISO 22081. We still read fH / mK the way the title block writes them — we do not silently remap.
f is fine. m is medium — the common machining conversation. c is coarse. v is very coarse and belongs on flame-cut or as-cast blanks, not a CNC housing.
Medium. Everyday brackets, covers, appliance-adjacent plates. Our plastic default conversation when the block is silent.
Fine. Precision faces, aerospace-adjacent hardware, medical-adjacent fittings — when you mean it. Fine on a 2 m panel is a cost.
Bluesky Tooling agreed default: fH-style metals, mK-style plastics. Ours, not an ISO-by-material rule. Stated on the inspection note. Standards →
Published deviations. This is the standard, not a Bluesky Tooling capability claim. We hold the class you write — or our default if you write nothing.
| Nominal size (mm) | f — fine | m — medium | c — coarse |
|---|---|---|---|
| 0.5 – 3 | ±0.05 | ±0.1 | ±0.2 |
| over 3 – 6 | ±0.05 | ±0.1 | ±0.3 |
| over 6 – 30 | ±0.1 | ±0.2 | ±0.5 |
| over 30 – 120 | ±0.15 | ±0.3 | ±0.8 |
| over 120 – 400 | ±0.2 | ±0.5 | ±1.2 |
| over 400 – 1000 | ±0.3 | ±0.8 | ±2.0 |
| over 1000 – 2000 | ±0.5 | ±1.2 | ±3.0 |
| Shorter leg (mm) | f | m | c |
|---|---|---|---|
| up to 10 | ±1° | ±1° | ±1°30′ |
| over 10 – 50 | ±0°30′ | ±0°30′ | ±1° |
| over 50 – 120 | ±0°20′ | ±0°20′ | ±0°30′ |
| over 120 – 400 | ±0°10′ | ±0°10′ | ±0°15′ |
| Nominal (mm) | f & m | c & v |
|---|---|---|
| 0.5 – 3 | ±0.2 | ±0.4 |
| over 3 – 6 | ±0.5 | ±1.0 |
| over 6 | ±1.0 | ±2.0 |
Below 0.5 mm the standard wants an individual tolerance. Shop talk on CNC metals is still ±0.05 mm general unless you write otherwise — see design guide.
A title-block class is cheap to inspect. A ±0.01 on every edge is not. Mark the exceptions.
| Use it when | Do not use it when | |
|---|---|---|
| ISO 2768 class | Most lengths are functional-enough. | A bore, a fit, or a seal must be tighter than the class. |
| Individual balloon | You will measure it incoming. | You are decorating the sheet. |
| Fit pair (H7/g6) | Two parts mate. Fits guide → | You wrote “snug” in a note. |
Any shop that cuts to a drawing. We will not list OEM marks we do not own.
Housings, plates, fixtures. f or m on the block; balloons on datums and fits.
Formed dims still need angles and inside R. A class does not invent springback.
mK-style talk. Shrink is not a metal fine class.
As-cast may live in c / v. Machined faces get their own balloons.
STEP plus a PDF. Files stay on this server.